GAKR3-60A Disconnect Switch Box Non-Fusible,Indoor&Outdoor,Meeting NEMA 3R Standards,Galvanized Steel,Anti Corrosion and Rust Prevention

Item No.: GAKR3-60A
It can normally close and open circuits under normal conditions. When a line fault occurs, the fuse blows to protect the equipment. During maintenance, it can completely disconnect the circuit to ensure personnel safety.
Description
Description

Product Description

Safety switch with fuse outdoor 3p 30A
This 3-Pole 30A Outdoor Safety Switch with integrated fuses provides reliable isolation and circuit protection for three-phase electrical systems in weather-exposed locations. Designed to IEC 60947-3 standards, it combines a manual disconnector with three 30A gG-type cartridge fuses within an IP65-rated enclosure suitable for rain, dust, and temperatures from -25°C to +60°C. The switch simultaneously disconnects all three phase conductors (L1, L2, L3) with a visible contact gap exceeding 4mm in the OFF position, ensuring safe maintenance conditions for systems rated at 400V AC 50/60Hz.It supports 35mm rail or M5 panel mounting. Tool-free fuse replacement is achieved by simply rotating the front cover handle 90 degrees to remove the fuse element, allowing maintenance without interrupting power. The switch mechanism utilizes a torsion spring snap-action design with a mechanical lifespan of 6,000 cycles.Typical applications include small photovoltaic power stations (less than 15kW), outdoor air conditioning units, irrigation pump control boxes, billboard power isolation, and workshop equipment power distribution.
Specification
Applications
1.Main incoming switch or branch circuit switch in outdoor distribution boards/boxes.
2.Power control and protection for garden water pumps, fountains, landscape lighting systems.
3.Power isolation and protection for outdoor AC units, heat pumps.
4.Power management for advertising light boxes, neon signs, LED displays.
5.Outdoor power distribution protection for construction sites, temporary facilities.
6.Power control for agricultural irrigation equipment, outdoor power tools.
7.Any outdoor single-phase electrical installation entry point requiring safe isolation and overcurrent protection.
Detailed Technical Specifications
Model: GAKR3-30A
Number of Poles: 3P (Three Poles). 
Fuse Type: Compatible with standard LV fuse links, such as:
gG/gL (Full Range Protection): General purpose, provides overload and short-circuit protection. Common sizes: 00 (14x51mm), 000 (22x58mm), 1 (22x58mm) etc. (Must match base).
Dimensions (length, width, height):44*20*27.5
Weight (gross/net):14/13
Safety Switch with Fuse Outdoor 3p 30A
Safety Switch with Fuse Outdoor 3p 30A
Safety Switch with Fuse Outdoor 3p 30A
Safety Switch with Fuse Outdoor 3p 30A
right elevation
left elevation
front elevation
Technical Specifications
(Custom configurations available upon request.)
parameter
Parameter value
Number of poles
3P
Rated current
30A
Shell material
steel
Safety Switch with Fuse Outdoor 3p 30A
Fuse
 The Essential Role of a Fuse: The Ultimate Barrier to Circuit Safety
Core Function:
Sacrificing Themselves to Preserve the System.A fuse is a passive overcurrent protection device. Its core mission is to forcibly cut off the current path by melting itself when a severe overload or short-circuit occurs. This:
1.Prevents wire overheating and fires
2.Prevents equipment from being damaged by overcurrent.Prevents cable/equipment damage from sustained overcurrentMelting element responds to heat generated by excessive current.
3.Protecting upstream distribution equipment (such as transformers and switchgear) from short-circuit current surges
4.Provides indirect electrical shock protection for personnel.
5.Interrupts ultra-high fault currents in milliseconds during phase-to-phase faults, containing arc energy and preventing catastrophic failure.
6.Ensures only the faulted circuit is isolated, maintaining power availability in other branches .